| 1. |
Ridge
Connecting Standard Tile - Used at the topmost row
of roof below Ridge Tiles. Eliminates use of cement
mortar. Facilities escape of warm air from below the
roof thus improves roof ventilation. |
| 2. |
Exhaust
Tile - Sits on top of UPVC vent pipe. It connects
UPVC vent pipe via a PVC reducer to collar tile and
ceramic vent set. Removes flashing need around UPVC air
vent pipe. For roof pitch 25º - 45º. |
| 3. |
Ridge
Connecting Double Tile - Same as Roof Connecting
Standard Tile but used only at left roof edge to match
Double Tiles. |
| 4. |
Ridge
End Cap - Used for capping horizontal ridge ends. It
overlaps on both Left and Right Verge Tiles to provide a
good finish. |
| 5. |
Left
Verge Tile - Same as Right Verge Tile but used
beneath Double Tile on left hand side of roof. |
| 6. |
Right
Verge Tile - Provide water-tightness to roof edge
and lends a solid appearance. Fixed onto wooden fascia
board beneath Standard Tiles on right hand side of roof. |
| 7. |
Double
Tile - Used at left edge of a straight roof to give
a similar wave finish at left edge of roof. |
| 8. |
Elbow
- Used at the bend (135ºC) of a horizontal/main ridge. |
| 9 |
Valley
Tile - Laid over metal valley gutter to give better
finish to roof valley. It allows proper seating and
securing of cut tiles with cement mortar. For roof pitch
of 20º - 40º. |
| 10. |
Eaves
Double Tile - Same as Eaves Standard Tile but used
only at left roof edge to match Double Tile. |
| 11. |
Eaves
Standard Tile - Used at the bottom most row of roof
i.e. eaves. It prevents vermin and bats from entering
roof. Besides, it provides a solid, elegant finish to
roof eaves. |
| 12. |
Ventilation
Tile - Facilities air flow below the roof. It
prevents water condensation and humidity on underside of
tiles. Installed across a roof slope at 5-feet spacing
and at 5th or 6th row from roof ridge. If used together
with Ridge Connecting Tiles and/or Ventilation Tape, it
greatly improves roof ventilation and brings down roof
temperature. |
| 13. |
Ridge
Tile - Used on horizontal/main ridge formed by 2
roof slopes. Internal width 220mm. Coverage 3 pieces/metre. |
| 14. |
3-Way
Apex - Used to cover a 3-way Intersection where roof
ridge meets with 2 hips. |
| 15. |
Hip
Tile - Used on inclined ridge i.e. Hip formed by 2
adjoining sloped roofs. Taper shape with internal width
140mm at head and 190mm at tail. 3 pieces/metre. |
| 16. |
Standard
Tile |
| 17. |
Hip
End - Starter tile at eaves area of a roof hip. It
gives aesthetic finishes and water-tightness. |
| 18. |
Eaves
Joint - Used where 2 roof eaves join for Hip
End/Ridge End to rest on it. Provides better finishing
and water-tightness. |